Diagram of the water situation as I found it when moving into the flat:
So, we have a meter in front on the house which marks the point at which the municipal water becomes “my” water. Directly from the meter (above ground) is single tap that is often used for watering plants and laundry. From the front tap the pipe enter the flat through the foundation and splits. One municipal branch goes up through the wall and enters the attic where it travels the length of the house before entering and filling a tank. The tank (approximately 1,000 liters) has a float valve similar to a toilet that regulates filling, and all plumbing for the flat runs off this single receptacle. The municipal second branch goes through the house with one tap in the kitchen and a second tap in the back marking the end of our water system.
You may be able to spot the problem. These tanks are a great idea as they provide storage and, being in the attic, tend to increase, or keep constant, the water pressure through both gravity and the “weight” of the water in the tank. The issue is that due to the very inconsistent municipal water (perhaps 4 hours a day) with very low pressure (made worse by most everyone pulling water when it is available) the tank rarely fills - and is never full.
The solution that most people, in similar situations, have adopted is the installation of a second tank at ground level (better municipal pressure) that can be used to fill the existing elevated tank. To do this, one needs the following:
1. A tank - 1000 liters or larger – I went with 1,300 liters)
2. A pump - either hand or electric - (I went with electric)
3. Piping from the municipal system into new tank
4. Piping from the new tank to the pump
5. Piping from the new tank to the existing tank
6. Electrical lines to the pump with a switch
7. Float valve for new tank
Diagram - First iteration of new tank set up:
The benefits of this system are/seemed to be that the existing infrastructure is utilized to pump water from the new to the old tank. An added benefit is/was that all the house municipal taps were pressurized while pumping – you could really get some pressure – and that the float valve in the old tank would shut off the flow in the event that one left the pump running for too long eliminating the need for an overflow system. The only negative, in my head, for this system was having to turn the tap outside to prevent a water “feed-back loop” in which the new tank would make a little recirculating water fountain. In the end, it did not work. Why? Well, I believe it was the length of pipe running though the house that the poor pump had to move water through before actually fighting gravity to fill the tank. Time to fill tank – 2.5 hours (but we had kick butt water pressure in the kitchen.
Diagram – second iteration of new tank setup:
The end of this sorted tale and the water system that has worked well for over 2 months now. External piping was run up the side of the flat – through the attic and into the tank. Fill time is 20 minutes and no running out to shut taps. The main negative is the bypass of the float valve making a major flood a very real possibility. An overflow system is installed, but it can only be a warning – ignore it and the bathroom becomes a waterfall.